{"product_id":"usr-can518-can-open-to-modbus-converter","title":"USR-CAN518 CAN-Open to Modbus Converter","description":"\u003ch2 class=\"box_4 flex-col\"\u003eUSR-CAN518 CAN-Open to Modbus Converter\u003c\/h2\u003e\n\u003cdiv class=\"product_center_Downloadbox\"\u003e\n\u003ch3 class=\"box_4 flex-col\"\u003e\u003cspan class=\"text_9\"\u003eOpen to Modbus Converter\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan class=\"text_8\"\u003e\u003cspan class=\"text_10\"\u003eUSR-CAN518 is a CANopen slave gateway independently developed by PUSR. It features 1 CAN interface, 1 RS485 interface, and 1 standard 10\/100M Ethernet interface. The device supports CANopen to Modbus conversion, making it easy to connect Modbus slave devices.\u003c\/span\u003e\u003c\/span\u003e\n\u003cdiv class=\"group_2 flex-row\"\u003e\n\u003cdiv class=\"commonproduct_btn commonproduct_btnpc\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"blue_text\"\u003eCANopen Slave to Modbus Master Converter\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"s_title\"\u003eCANopen Slave | Modbus TCP\/RTU Master | Full Isolation | Industrial Designed\u003c\/span\u003e\u003cspan class=\"s_text\"\u003eUSR-CAN518 is a CANopen slave gateway independently developed by PUSR. It features 1 CAN interface, 1 RS485 interface, and 1 standard 10\/100M Ethernet interface. The device supports CANopen to Modbus conversion, making it easy to connect Modbus slave devices on industrial sites to CANopen master devices such as PLCs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"s_text\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/038d08b9cf02747d1428716b0bd2dee0.jpg?v=1784380667\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"black_text\"\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"custom-lists\"\u003e\n\u003cli\u003eProtocol Conversion: CANopen slave to Modbus TCP master | CANopen slave to Modbus RTU master;\u003c\/li\u003e\n\u003cli\u003eIndustrial Design: EMC Protection Level 3 | -40 ~ +85℃\u003c\/li\u003e\n\u003cli\u003eFull Isolation: Isolation for both serial ports, Ethernet port, power circuit\u003c\/li\u003e\n\u003cli\u003eWide Power Input: 9-36V DC\u003c\/li\u003e\n\u003cli\u003eRich Hardware Interface: 1*CAN, 1*RS232\/RS485, 1*Ethernet port\u003c\/li\u003e\n\u003cli\u003eEasy to Use: User friendly utility for parameters configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/2fb5e08b1a56647439db7ff43a38131e.jpg?v=1784380667\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"black_text\"\u003eCAN Series Products PUSR\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"s_text\"\u003eoffers a series of CAN devices, which feature high speed, low latency, stable performance, simple operation, and good cost-effectiveness. They support CAN 2.0A\/B to RS232\/485\/Ethernet, CAN FD to RS232\/485\/Ethernet, CAN FD to Modbus gateway, CAN FD to WiFi, CANopen slave to Modbus master, CANopen master to Modbus slave, CANopen to PROFINET, and CAN analyzers, etc. Users can choose the appropriate product according to their needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/f4a2500487c85f0002030939cc143c8d.jpg?v=1784380668\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"black_text\"\u003eCANopen Slave to Modbus TCP Master\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"s_text\"\u003eThe gateway acts as CANopen slave to connect upper-layer CANopen master device, meanwhile works as Modbus TCP master to access laser radar, load cell, scanner and other Modbus TCP field devices. Realizes seamless data interconnection of heterogeneous devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/ef6827bfab5487751caf6e69ee7c9b01.jpg?v=1784380667\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"black_text\"\u003eCANopen Slave to Modbus RTU Master\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"s_text\"\u003eCompatible with traditional RS485 industrial field devices. Gateway connects upper CANopen master (PLC\/SCADA system), and accesses sensors, instruments, smoke alarms via Modbus RTU bus, expands traditional serial device access for CANopen network.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/342b7165e6022266d1b1da55852c11c8.jpg?v=1784380667\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"black_text\"\u003eEasy Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"s_text\"\u003eThe USR-CAN518 has a user-friendly setup tool that lets you quickly set up protocol conversion routines for most applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/5792154625181ffeceb4492d470fb2b4.jpg?v=1784380668\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"black_text\"\u003eDesigned for Demanding Industrial Environments\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"custom-lists\"\u003e\n\u003cli\u003eEMC protection: level 3\u003c\/li\u003e\n\u003cli\u003eWide operating temperature: -40℃~+85℃\u003c\/li\u003e\n\u003cli\u003eDual watchdog: hardware \u0026amp; software watchdog, ensure stable operating\u003c\/li\u003e\n\u003cli\u003eWide power input: DC 9-36V, supports power input anti-reverse\u003c\/li\u003e\n\u003cli\u003eFull lsolation: 3000VDC isolation for power, serial ports, Ethernet port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/6ae73f0b3c541e1e40495fdfc637030d.jpg?v=1784380667\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"black_text text_ads\"\u003eApplication\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"custom-lists\"\u003e\n\u003cli\u003eIndustrial Automation\u003c\/li\u003e\n\u003cli\u003eIntelligent Logistics AGV\u003c\/li\u003e\n\u003cli\u003eWater\/Wind\/Solar Engineering\u003c\/li\u003e\n\u003cli\u003eSmart Machine Toll\u003c\/li\u003e\n\u003cli\u003eSmart Building\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/03c8274678a5df23798bbf77f8f89d0d.jpg?v=1784380668\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"cont_boxcont flex-col\"\u003e\u003cspan class=\"black_text text_ads\"\u003eDimension \u0026amp; Interface\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"custom-lists\"\u003e\n\u003cli\u003eDimension: 110 * 27 * 76.1mm\u003c\/li\u003e\n\u003cli\u003eType-C: For debugging and firmware upgrading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/511839c03acc205c1bda4b2d48909639.jpg?v=1784380667\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"total\"\u003e\n\u003ch3 class=\"total-title\"\u003eDocuments\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"file\"\u003e\n\u003cdiv class=\"file-left\"\u003e\n\u003cdiv class=\"file-left-icon-and-title\"\u003e\n\u003cdiv class=\"file-title\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/USR-CAN518-spec-V1.0.0.pdf?v=1784381187\" style=\"color: rgb(255, 42, 0);\"\u003eUSR-CAN518-spec-V1.0.0\u003c\/a\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"file\"\u003e\n\u003cdiv class=\"file-left\"\u003e\n\u003cdiv class=\"file-left-icon-and-title\"\u003e\n\u003cdiv class=\"file-icon\"\u003e\n\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ci class=\"iconfontaa icon-view_icon_file_fill\"\u003e\u003c\/i\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"file-title\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/USR-CAN518_User_Manual_V1.0.0.pdf?v=1784381187\" style=\"color: rgb(255, 42, 0);\"\u003eUSR-CAN518 User Manual V1.0.0\u003c\/a\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"file-title\"\u003e\n\u003cdiv class=\"total\"\u003e\n\u003cdiv class=\"total-title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3 class=\"total-title\"\u003eUtilities\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"file\"\u003e\n\u003cdiv class=\"file-left\"\u003e\n\u003cdiv class=\"file-left-icon-and-title\"\u003e\n\u003cdiv class=\"file-title\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca href=\"https:\/\/www.pusr.com\/wiki\/puba\/bmCAV0sAH?lang=en_US#:~:text=Share-,Utilities,CAN518(CANopen_Slave)_v1.0.0.0.exe,-07%2D15%2009\" style=\"color: rgb(255, 42, 0);\"\u003eCAN518(CANopen_Slave)_v1.0.0.0\u003c\/a\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"USR IOT","offers":[{"title":"Default Title","offer_id":47959468081388,"sku":"USR-CAN518","price":99.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1386\/3791\/files\/usr-iot-can-bus-usr-can518-can-open-to-modbus-converter-1249588919.png?v=1789743310","url":"https:\/\/iot-store.com.au\/products\/usr-can518-can-open-to-modbus-converter","provider":"IOT Store","version":"1.0","type":"link"}