Industrial IQFLOW Compact 9-in-1 Weather Station Sensor RS485

  • $899.00
  • Save $100
  • (Exc. GST)


  • Available to order with a short lead time. Ship within 10-20 days.

  • $ We Ship from our stock in AU (Perth) with pickup option, and Prices are Exc. GST
  • $ We Offer Quantity Discounts for Large Orders 10+ qty (Request for Quote)
  • $ We Accept Purchase Orders & Net 30 Payment for Eligible Accounts
  •  

    Industrial IQFLOW Compact 9-in-1 Weather Station Sensor RS485

    The IQFLOW 9-in-1 weather station Sensors can measure these 9 parameters: Wind Speed, Wind Direction, Temperature, Humidity, Air Pressure, Illumination, PM2.5, PM10, Noise & Rain Gauge.

    Features: 

    • Power Input: 10 ~ 30VDC
    • Max Power Consumption: 1.2W
    • Wind Speed, Wind Direction, Temperature, Humidity, Air Pressure, Illumination, PM2.5, PM10

    Sensor Spec:

    Wind Speed:

    • Range: 0~60m/s
    • Accuracy: ±(0.2m/s±0.02*v)(v : the wind speed)
    • Ultrasonic measurement, no start wind strength needed

    Wind Direction:

    • Range: 0~359°
    • Accuracy: +3°
    • Ultrasonic measurement, no start wind strength needed
    • Built-in electronic compass. No need to consider the installation direction

    Temperature:

    • Range: -40°C ~ +80°C
    • Accuracy: +0.5°C

    Humidity:

    • Range: 0 ~ 99% RH
    • Accuracy Tolerance: Typ +3% RH

    Air Pressure:

    • Accuracy: ±0.15kPa@25°C 101kPa
    • Range: 0~120kPa

    Noise:

    • Range: 30dB~120dB
    • Accuracy: +0.5dB

    PM2.5:

    • Range: 0~1000ug/m3
    • Accuracy: ±3%FS
    • Resolution: 1ug/m3

    PM10:

    • Range: 0~1000ug/m3
    • Accuracy: +3%FS
    • Resolution: 1ug/m3

    llumination:

    • Range: 0~200k Lux
    • Accuracy: +7%(25 °C)

    Sensor Table:

    Sensor Type Type Code Range Length( Bytes) Example
    Wind Speed 0x01

    Speed: 0 ~ 60m/s

    0x02 

    0x0028/100=0.40m/s

    Wind Level 0x02 Wind Level: (0 ~18) 0x02 0x0002=2(Current wind level)

    Wind Direction

    0x03 Direction: 0~7 0x02

    0X0004=3(Due north is 0, increasing clockwise, and due east is 2)

    Wind Angle 0x04

    Angel: 0 ~ 359°

    0x02

    0x02C9/10=66.6°(Due north is 0°, increasing clockwise, due east is 90°)

    Humidity 0x05 Hum: 099%RH 0x02 0x0164/10=35.6%RH 
    Temperature 0x06 Temp: -40 ~ +80°C 0x02

    0xFFDD/10=-3.5°C  

    Noise 0x07 Nosie: 30~120dB 0x02

    0x023e/10=57.4dB

    PM2.5 / CO2

    0x08

    PM2.5: 01000μg/m3

    CO2: 0~5000ppm

    0x02

    0x0023=35μg/m

    0x04fb=1275ppm

    PM10 0x09

    PM10: 01000μg/m3

    0x02

    0x002D=45μg/m

    Pressure 0x0A 0~120kPa/y 0x02

    0x2748/10=1005.6kPa    

    illumination 0x0B 0200000kLux 0x04 0x04D2*10=12340kLux  

     

    Default RS485 Address: 0x01

    original address function code  register address high register address low Reserved 1 New address CRC16    low CRC16  high
    0X01 0X06 0X00 0X30 0X00 0X02 0X08 0X04

     

    address function code start register address high start register address low Register length high Register length is low CRC16    low CRC16  high
    0X01 0X03 0X00 0X00 0X00 0X02 0XC4 0X0B

     

    Address Function code Data length Register 0 data high Register 0 data low Register 1 data high Register 1 data low CRC16 low CRC16 high
    0X01 0X03 0X04 0X00 0X24 0X00 0X03 0XFA 0X39