CAN Isolator click provides isolated CAN communication. It carries the ADM3053 signal and power isolated CAN transceiver with an integrated isolated DC-to-DC converter. The click is designed to run on either 3.3V or 5V power supply. CAN Isolator click communicates with the target microcontroller over UART interface.

The click carries a DB 9-pin male connector.
ADM3053 features
The ADM3053 is an isolated controller area network (CAN) physical layer transceiver with an integrated isolated DC-to-DC converter.
The ADM3053 creates a fully isolated interface between the CAN protocol controller and the physical layer bus. It is capable of running at data rates of up to 1 Mbps.
Connector features
This is a standard DB 9-pin male connector.

Specifications
Type |
CAN,Isolator |
Applications |
CAN data buses, Industrial field networks |
On-board modules |
ADM3053 CAN transceiver, DB 9-pin connector |
Key Benefits |
No need for an external supply for the isolated side |
Interface |
UART |
Input Voltage |
3.3V or 5V |
Compatibility |
mikroBUS |
Click board size |
L (57.15 x 25.4 mm) |
Pinout diagram
This table shows how the pinout on CAN Isolator click corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).
Notes |
Pin |
 |
Pin |
Notes |
|
NC |
1 |
AN |
PWM |
16 |
NC |
|
|
NC |
2 |
RST |
INT |
15 |
NC |
|
|
NC |
3 |
CS |
TX |
14 |
RXD |
Receiver Output Data |
|
NC |
4 |
SCK |
RX |
13 |
TXD |
Driver Input Data |
|
NC |
5 |
MISO |
SCL |
12 |
NC |
|
|
NC |
6 |
MOSI |
SDA |
11 |
NC |
|
Power supply |
+3.3V |
7 |
3.3V |
5V |
10 |
+5V |
Power supply |
Ground |
GND |
8 |
GND |
GND |
9 |
GND |
Ground |
Jumpers and settings
Designator |
Name |
Default Position |
Default Option |
Description |
JP1 |
VIO.SEL. |
Left |
3V3 |
Power Supply Voltage Selection 3V3/5V, left position 3V3, right position 5V |
JP2 |
SLOPE SEL |
Left |
HI |
Slope select, default high rate, right option the slope is limited |